Similink create 2 Initialize Procs

4 visualizzazioni (ultimi 30 giorni)
hoa phan
hoa phan il 29 Giu 2023
Risposto: Harsh il 20 Feb 2025
Hi,
I use Matlab to generate code and the output generated code as below:
FUNC(void, DASwCpt_SentAcqn_CODE) DASwCpt_SentAcqn_Proc_Ini(void)
{
...
}
FUNC(void, DASwCpt_SentAcqn_CODE) RE_DASwCpt_SentAcqn_Initialize(void)
{
/* (no initialization code required) */
}
I don't know why it always create the RE_DASwCpt_SentAcqn_Initialize proc,
How to setup the model to avoid creating this proc
Thanks

Risposte (1)

Harsh
Harsh il 20 Feb 2025
You can remove the zero-initialization code for internal data in the following ways:
  • Open the Configuration Parameters dialog box. On the Optimization pane, select Remove internal data zero initialization
  • Use the following command prompt to set the model parameter ZeroInternalMemoryAtStartup to off
set_param(model, 'ZeroInternalMemoryAtStartup', 'off');
For more information regarding this please use the following command to view the documentation-
doc Remove Zero Initialization Code