Simscape Battery Block Parameterization Manager: Datasheet Derived Values for Terminal Resistance R0 of Molicel Battery Cell
17 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Fynn-Brian Semmler
il 31 Gen 2024
Commentato: Fynn-Brian Semmler
il 7 Mag 2024
Hello,
i am using the Block Parameterization Manager: Battery (Table-Based) to use pre-parameterize battery cells in my Simulink Simscape model. I am wondering where some data is coming from, specifically the values for R0 (Terminal Resistance) of the Molicel INR_21700_P45B.
In the manager, its says datasheet derived. Is it possible to view this datasheet somewhere? Is there a database for it?
Thank you very much for your help!
Best
1 Commento
Kautuk Raj
il 15 Feb 2024
The datasheets can be typically found on the manufacturer website, in this case here: https://www.molicel.com/wp-content/uploads/INR21700P45B_1.2_Product-Data-Sheet-of-INR-21700-P45B-80109.pdf
Risposta accettata
Javier Gazzarri
il 6 Mag 2024
Hello Fynn-Brian
Thank you for your question.
The internal resistance is calculated based on pairs of constant current discharge curves as R ~ deltaV / delta I.
Please let me know if you have any other question.
Best regards,
Javier
Più risposte (0)
Vedere anche
Categorie
Scopri di più su Simscape Battery in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!