photo

Javier Gazzarri

Last seen: 24 giorni fa Attivo dal 2014

Followers: 23   Following: 0

Messaggio

Statistica

All
MATLAB Answers

0 Domande
79 Risposte

File Exchange

1 File

RANK
609
of 300.331

REPUTAZIONE
130

CONTRIBUTI
0 Domande
79 Risposte

ACCETTAZIONE DELLE RISPOSTE
0.00%

VOTI RICEVUTI
17

RANK
193 of 20.920

REPUTAZIONE
6.901

VALUTAZIONE MEDIA
4.90

CONTRIBUTI
1 File

DOWNLOAD
158

ALL TIME DOWNLOAD
64672

RANK

of 168.124

CONTRIBUTI
0 Problemi
0 Soluzioni

PUNTEGGIO
0

NUMERO DI BADGE
0

CONTRIBUTI
0 Post

CONTRIBUTI
0 Pubblico Canali

VALUTAZIONE MEDIA

CONTRIBUTI
0 Punti principali

NUMERO MEDIO DI LIKE

  • Knowledgeable Level 4
  • Knowledgeable Level 3
  • 5-Star Galaxy Level 5
  • Personal Best Downloads Level 4
  • First Review
  • First Submission
  • 3 Month Streak
  • Revival Level 2
  • First Answer

Visualizza badge

Feeds

Visto da

Risposto
Predicting Thermal Runaway on Lithium Ion Battery under Heating conditions
Hello Dan, Thank you for your inquiry. If you open the Battery Thermal Runaway subsystem dialog box, go to the Description tab...

circa un mese fa | 0

Risposto
Li-ion cell Hysteresis Parameter Estimation
Hello Chinmaya, Thank you for reaching out. Glad to hear about your progress. 1- Slow charge/discharge curves are not adequate...

circa un mese fa | 0

Risposto
How can one determine impedances at different characteristic frequency values in an EIS curve?
Hello Ekagra, You can use the scripts described here to find ECM parameters based on your spectrum: Estimate Battery Model Para...

4 mesi fa | 0

Risposto
Parameters are not estimated for the SOC range 0- 60% while using parameter estimation application of MATLAB. How to resolve?
Hello Girisha Please check the cell capacity that you defined. The tool uses coulomb counting based on the total capacity to d...

4 mesi fa | 0

Risposto
ISSUE WITH SIMULATING BATTERY CELL AFTER PARAMETER ESTIMATION TASK?
Hello SUDEEP Please check the capacity value you entered in the block. If it is lower than the actual capacity then the battery...

4 mesi fa | 0

Risposto
How can I externally modify (without accessing the dialog box) the mask parameters of a Simscape element?
Hello Daniel, As Yifeng explained above, the parameters in Simscape blocks are read at initialization and cannot change during...

4 mesi fa | 0

Risposto
Using batteryParametersLUT function to determine ECM parameters with HPPC discharge test
Hello Lily, I believe the issue is that your block has current directionality enabled. This duplicates the parameter fields to ...

4 mesi fa | 0

Risposto
how to make AC or DC load vary on simulink?
Hello Muhammad, Please let me know if this is an acceptable to you: 1) Connect the load signal to the MULTIPLY port of a Divid...

4 mesi fa | 0

Risposto
I want to implement charging and discharging of 48V lead-acid batteries used in light electric vehicles (2-wheelers, 3-wheelers) using CC-CV-FLOAT mode
Hello Sanjid, thank you for your question. Here is an example of a system that uses a PbA battery model autoElectrical I recom...

4 mesi fa | 0

| accettato

Risposto
Li-ion cell Hysteresis Parameter Estimation
Hello Chinmaya, I'd recommend C/20 or lower. C/5 is still too high to avoid ohmic losses. Your profile goes back to 100% in th...

4 mesi fa | 0

Risposto
Change Capacity in Specialized discharge profile battery model
Hello Gokul, I believe what we are seeing responds to the definition of the different types of capacities. e.g. total, discharg...

4 mesi fa | 0

Risposto
Li-ion cell Hysteresis Parameter Estimation
Hello Chinmaya, In 2025a, Model Based Calibration (MBC) includes a template for ECMs with hysteresis. Calibrate Powertrain Bl...

4 mesi fa | 1

| accettato

Risposto
How to Use command to remove lines between physical models?
Hello 季, I am investigating the proper way to get a proper handle to the connection line you want to delete and I'll get back t...

4 mesi fa | 0

| accettato

Risposto
Error when change battery parallel and/or series cells in battery module assembly
Hello Luis, Glad to hear you found the problem. Another point for you to consider is that you do not need to change the .ssc f...

9 mesi fa | 0

Risposto
The thermal port for the battery seems to be not modeled using the code.
Hello Umesh, I cannot find the battery pack definition in your code above. I see you defined a module assembly but not a pack. ...

oltre un anno fa | 0

Risposto
How do we determine length and width of Pack object in Battery Builder?
Hello Son, Say you have a battery object called Battery. You can access these properties by typing: Battery.XExtent Battery.Y...

oltre un anno fa | 0

| accettato

Risposto
Using Coulomb Counting Method for SoC Estimation of battery
Hello Ranish. Please bear in mind that the above calculation is only valid under the approximation that the voltage is constant...

oltre un anno fa | 0

| accettato

Risposto
Battery Charging and Discharging
Hello Mohamad, Would something like this Current Profile be what you are looking for? Battery State-of-Charge Estimation - MAT...

oltre un anno fa | 0

Risposto
Simscape Battery Block Parameterization Manager: Datasheet Derived Values for Terminal Resistance R0 of Molicel Battery Cell
Hello Fynn-Brian Thank you for your question. The internal resistance is calculated based on pairs of constant current discha...

oltre un anno fa | 0

| accettato

Risposto
Parameter estimation. Different temperature values
Hi Elvir, No, you don't need to worry about that. The isothermal simulation does not need any temperature setting on your part....

oltre un anno fa | 0

Risposto
Parameter estimation. Different temperature values
Hi Elvir, The parameter estimation procedure is intended to be used on an isothermal experiment. The results you obtain are, th...

quasi 2 anni fa | 0

Risposto
Li-ion battery pack aging
Hello Nalla, Please consider using the passive balancing block in Simscape Battery. Connecting this to the battery pack will be...

circa 2 anni fa | 0

Risposto
Li-ion battery R0 value
Hello Nalla, The R0 growth will depend on the type of cell, operating and environmental conditions. It is information you need ...

circa 2 anni fa | 0

Risposto
Run Current Profiles on a cell and only receive simulated results
Hi Katarina, Certainly. If you need to run one or several current profiles through your model, please connect a controlled curr...

circa 2 anni fa | 0

Risposto
Run Current Profiles on a cell and only receive simulated results
Hello Katarina, The task you are describing is the validation of the estimated parameters. You need to specify the validation c...

circa 2 anni fa | 0

Risposto
Causality for FMU in simscape electrical : how to separate an electrical conserving port into 2 physical or simulink signal ports to create an FMU with it.
Hello Enzo, Do you want to create an FMU block for both components connected in series, or one FMU block for each of them? In...

circa 2 anni fa | 0

Risposto
How to debug .ssc file for custom simscape component
Hello Sudhanshu, Hitesh, The equivalent to a breakpoint is not possible in Simscape because the code in an ssc file is not exec...

circa 2 anni fa | 0

Risposto
Cell balancing of Li-on battery
Hello Nalla, When I run your model I can see the temperature output (please make sure you enable temperature effects) and the c...

circa 2 anni fa | 0

Risposto
Setting Aging parameters in generic battery model (battery mask)
Hello Jarin, Aging parameters are typically difficult to find in datasheets and sometimes you need to cycle the battery to find...

circa 2 anni fa | 0

Risposto
Choosing a machine learning model for predicting the results of a process
Hello Fabian, Great use case for Machine Learning. In MATLAB you can actually try several ML algorithms simultaneously and pic...

circa 2 anni fa | 0

Carica altro