Simulating for U channel cooling system using own battery pack.
6 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Error:Error compiling Simscape network for model BatteryWithCollingPlate.
Caused by:
Connection 'connect(Module1.BottomExtClnt,U_shaped_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x1' and '1x42'. The arguments in a connection must be of the same size.
0 Commenti
Risposta accettata
Kautuk Raj
il 14 Feb 2024
Spostato: Joel Van Sickel
il 20 Feb 2024
I suggest verifying the the sizes of the ports on both components (Module1.BottomExtClnt and U_shaped_Channels.Side1). As the error message states, to resolve this issue, you need to ensure that the ports being connected have the same size.