Why does my Transfer function overshoots
Mostra commenti meno recenti
syms s real
zeros = roots([0.075, 1, 1]);
poles = roots([1, 3, 5, 0]);
Gs = zpk(zeros, poles,1);
rlocus(Gs)



As you can see, eventhough K=45.3 is on the root locus with damping coeff. 1 it still overshoots. What might cause this problem or am i doing something wrong ?
1 Commento
Onur Arda
il 3 Mag 2024
damn
Risposta accettata
Più risposte (1)
Hi @Berker
I believe the design objective is to determine the gain from the root locus such that the response avoids exhibiting oscillatory behavior or maintains the percentage overshoot as low as possible without becoming overdamped. If the plant is given as follows,

then the design procedure can be referred to:

%% Plant
zeros = roots([0.075, 1, 1]);
poles = roots([1, 3, 5, 0]);
Gp = zpk(zeros, poles, 0.075)
% Gp = tf([0.075, 1, 1], [1, 3, 5, 0]) % directly models the Plant
%% Check if the Gain is as accurate as shown in the data tip (rlocus)
[r, k] = rlocus(Gp);
idx = find(abs(imag(r(1,:)) < eps));
rlGain = k(idx(1))
%% True Control Gain
Gc = rlGain*(1/0.075);
%% Closed-loop system
Gcl = feedback(Gc*Gp, 1)
step(Gcl), grid on
1 Commento
If following your original plant's zpk transfer function, you will still find the root locus gain to be around 45.3, and the same design procedure remains applicable.
%% Plant
zeros = roots([0.075, 1, 1]);
poles = roots([1, 3, 5, 0]);
Gp = zpk(zeros, poles, 1) % <-- k is 1
% Gp = tf([0.075, 1, 1], [1, 3, 5, 0]) % directly models the Plant
%% Check if the Gain is as accurate as shown in the data tip (rlocus)
[r, k] = rlocus(Gp);
idx = find(abs(imag(r(1,:)) < eps));
rlGain = k(idx(1))
%% True Control Gain
Gc = rlGain*(1/0.075);
%% Closed-loop system
Gcl = feedback(Gc*Gp, 1)
step(Gcl), grid on