Is it possible to access the blocks inside the model under test from the test harness in custom criteria script of simulink test?
4 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Jerome Almon
il 13 Ago 2024
Commentato: Fangjun Jiang
il 13 Ago 2024
I would like to verify the datatype of inports and outports of a model in simulink test. So I created a test harness for it and when I try to access the inports inside the model under test in test harness from the custom cirteria script of simulink test, it doesnt work.
function ioAnalysisFunc(test)
res = get_param(strcat(test.sltest_bdroot, '/Model1/Inport1'), 'OutDataTypeStr'); % Here test.sltest_bdroot is the test harness 'Model1_Harness'
assignin('base', 'ress_out', res{1});
end
The error thrown is,
--------------------------------------------------------------------
Error occurred in custom criteria and custom criteria assessment did not run to completion.
--------- Error ID: ---------
Simulink:Commands:InvSimulinkObjectName
-------------- Error Details: --------------
Invalid Simulink object name: 'Model1_Harness/Model1/Inport1'.
--------------------------------------------------------------------
0 Commenti
Risposta accettata
Fangjun Jiang
il 13 Ago 2024
I think the testing harness model is using the Model block to reference the model under test, so you can't access the block directly like that inside a model reference.
I would suggest getting the data type of the signal that is feeding into "Inport1". In most cases, it is the same as the data type of the output of "Inport1".
2 Commenti
Fangjun Jiang
il 13 Ago 2024
Not sure if you are familar with Model Reference. Modle under test is referenced this way.
Più risposte (0)
Vedere anche
Categorie
Scopri di più su Inputs in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!