- What release are you using?
- Are you specifying a custom timing database you generated using genhdltdb with TimingDatabaseDirectory?
Characterisation error in HDL code generation?
3 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
When generating RTL code for VHDL for an Artix-7 using FPGA-In-The-Loop, I'm met with these error messages and only the first section of the design is characterised. The critical path is given as 0ns.
Unexpected error during HDL Code Generation.
Contact support@mathworks.com with reproduction steps.
Assertion failed with debug message:
B:\matlab\src\cgir_hdl\target_analysis\ParameterizedDatabaseReader.cpp:101:paramChar
Error in characterization.readCharacterizationData
Error in slhdlcoder.HDLCoder/runPIRTransformAndCodegen
Error in slhdlcoder.HDLCoder/makehdl
Error in downstream.DownstreamIntegrationDriver/runGenerateRTLCodeAndTestbench
Error in runGenerateRTLCodeAndTestbench
Error in Simulink.ModelAdvisor/executeCheckCallbackFct
Error in Simulink.ModelAdvisor/run
Error in Simulink.ModelAdvisor/runCheck
Error in ModelAdvisor.Node/runTaskAdvisor'
1 Commento
Steven Hatcher
il 7 Ott 2024
Hi Dylan,
Steven
Risposte (1)
Kiran Kintali
il 7 Ott 2024
Modificato: Kiran Kintali
il 7 Ott 2024
This is an unexpected error. What version of MATLAB are you using?
Can you share the model? Do not hesitate to reach out to tech support for a workaround. Thanks