Hit time invalid error message while runing in simulink
15 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Hello,
Simulation while runing in simulink was stopped and the following message was occurred.
"The next hit time(-429.4967296) for variable sample time(tid=4) is invalid because it is either less than or not sufficiently greater than the current time (429.49672949999996)."
Simulation constraints are like this :
- Accelerator mode
- solver options : variable step, ODE23, max step 1e-7, relative tolerance 1e-3, min step size, absolute tolerance, initial step size : auto
I am looking forward to your good opinion. Thank you.
7 Commenti
Walter Roberson
il 1 Giu 2015
Re-reading I think the problem is the min step size, that you should set it specifically and make it 1E-8 or smaller.
Risposte (0)
Vedere anche
Categorie
Scopri di più su General Applications in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!