Incremental Conductance in simulink
1 visualizzazione (ultimi 30 giorni)
Mostra commenti meno recenti
Hey guys,
I've successfully modeled my solar aray in simulink and am getting correct output, but I'm having some trouble modeling an MPPT using the incremental conductance method.
if anyone has a model of it or can point me in the right direction I'd greatly appreciate it.
Thanks.
0 Commenti
Risposte (1)
Tony Castillo
il 15 Gen 2018
Modificato: Guillaume
il 4 Ago 2019
function dc = IC( V, I, Adc, dcinit)
%#codegen
%Algoritmo IncrementalConductance mi referencia es la dI/dV
% Isc=input ('Corriente de corto circuito=');
% Voc=input('Voltaje de circuito abierto=');
% Adc=3e-4; %variacion de ciclo de trabajo
persistent dcold Vold Iold
dataType = 'double';
if isempty(Vold)
Vold=0;
Iold=0;
dcold=dcinit;
end
%calculo de errores
dV=V-Vold;
dI=I-Iold;
%
if dV==0
if dI==0
dc =dcold;
return
else
if dI>0
dc = dcold - Adc; %reduce V
else
dc = dcold + Adc; %incrementa V
end
end
else
if I+(dI/dV)==0
dc=dcold;
return
else
if I+(dI/dV)>0
dc = dcold + Adc; %incrementa V
else
dc = dcold - Adc; %reduce V
end
end
end
dcmax=0.95; %esto es para limitar los máximos y minimos del dc
dcmin=0.05;
if dc>=dcmax || dc<=dcmin
dc=dcold;
end
dcold=dc;
Vold=V;
Iold=I;
0 Commenti
Vedere anche
Categorie
Scopri di più su Solar Power in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!