i want to change my resistor value from gui... i gave for example set_param('MyModel/MySubsystem/MyBlock','resistance','10'); but it shows Myblock does not have resistance parameter.. help me to solve this problem

Risposta accettata

Azzi Abdelmalek
Azzi Abdelmalek il 13 Giu 2015
Modificato: Azzi Abdelmalek il 13 Giu 2015
To get the reals names of your parameters type
get_param('MyModel/MySubsystem/MyBlock','DialogParameters')
The name of the parameter you want to change is R, not resistance.
set_param('MyModel/MySubsystem/MyBlock','R','10')