I'm charging a 40V, 50Ah Lead acid battery using buck converter and PI control on battery voltage and current. Simulink 2012b hangs after half an hour of simulation maybe because of data storage. Please suggest me what can be done.

2 visualizzazioni (ultimi 30 giorni)
The simulation takes a lot of time. Please let me know what can me done to improve simulation take also. The battery charges on hourly basis, but when the simulation is run for more than half an hour, Matlab 2012b hangs and nothing can be done but restart Matlab. I'm using inductor and power components for simulation, I have seen that power components does increase the simulation time. I do guess because of the data stored in workspace the Matlab is getting hanged. Please provide me suggestions to perform this simulation.
  2 Commenti
Tony Castillo
Tony Castillo il 7 Giu 2016
Hi Ravindra, i'm having a similar problem for charge my battery, did you solve it?, but i'm working with SimPowerSystem 2015B, if you solve it, can you help me?.

Accedi per commentare.

Risposte (1)

Joel Van Sickel
Joel Van Sickel il 24 Set 2020
Hello Ravindra,
please update to a newer version of matlab, and utilize simscape components. Start here: https://www.mathworks.com/help/physmod/simscape/ug/lead-acid-battery.html
Otherwise try adding snubber resistors and switching to a fixed time step simulation. You should also reduce the amount of data being saved.
Regards,