C2000 ePWM block on Simulink to trigger two ADC channels?
3 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I'd like to trigger two ADC channels on the F28377S Launchpad using Simulink, however, I do not know how to set up the ePWM block to trigger the ADCs one after the other but not at the same time. Can someone please guide me through the ePWM block parameters to achieve this?
Thanks!
0 Commenti
Risposte (1)
Sumith Sekharan
il 26 Mag 2016
Hi Solomon, For F28377S processor there is no simultaneous sampling option. But you can achieve the same using 2 ADC modules. You can select the same PWM event trigger for both the modules. This should allow you to sample two channels with the same PWM event.
Hope this helps. Let me know.
Thanks, Sumith