How do I get a magnitude respons with frequency at the x-axis?
3 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Joakim Hansen
il 19 Ott 2017
Commentato: Star Strider
il 20 Ott 2017
When I use the function freqz() I'll get a response with normalized frequency at the x-axis. Is there a way to get the freqency instead or optionally calculate it by hand?
0 Commenti
Risposta accettata
Star Strider
il 19 Ott 2017
Yes!
Supply the sampling frequency (here ‘Fs’) as an argument to freqz to get the plot in terms of actual frequency (from 0 Hz to the Nyquist frequency), where ‘NFFT’ is the length of the Fourier transform you want to use (a good choice being 2^16):
freqz(sos, NFFT, Fs)
or:
freqz(b, a, NFFT, Fs)
or others, depending on how you implemented your filter.
2 Commenti