what do the variable P,I and D mean in PID(z) in simulink?

5 visualizzazioni (ultimi 30 giorni)
Hello, As you saw in my question, do P.I and D means Ku(ultimate gain),Ti and Td respectively when using the PID from simulink? thanks
  1 Commento
Guillaume
Guillaume il 5 Feb 2018
Modificato: Guillaume il 5 Feb 2018
We could turn back the question back on you and ask what do the variable Ku, Ti and Td mean for you?
They're obviously the proportional, integral and derivative constant respectively. What they mean exactly is completely documented in the help.

Accedi per commentare.

Risposta accettata

SimTec
SimTec il 7 Feb 2018
Hello Birdman and Thank you so much for your help. So what I understood is that I have to write the value in the PID(z) in simulink as showed in the pictures.is it correct!

Più risposte (3)

Jim Riggs
Jim Riggs il 5 Feb 2018
See the link to help in Guillaume's comment:
Proportional
Integral
Differential

SimTec
SimTec il 6 Feb 2018
Sorry, My question was wrong. I know those what they mean but my question when it comes to tuning a PID. in the PID(z) controller, I see P,I and D, using Ziegler Nichols, SHould I put the value calculated like P=Ku,I=Ti and D=Td or P=Kp,I=Ki and D=Kd? thanks

Birdman
Birdman il 6 Feb 2018
This question can be answered in different aspects but let me start from explaining them in this way:
If you are going to write IDEAL(not reasonable in this form) PID structure, you may write it as follows:
PID(s)=(Kd*s^2+Kp*s+Ki)/s
and also, a second form, which is also widely used IDEAL(not reasonable in this form), is as follows:
PID(s)=Ku*(1+(1/Ti*s)+(Td*s))
Which one to use is totally up to the user. In the first form, you can think of each term as independent because every term has its gain and by setting each of them, you design a PID. In second form, you have a global gain for your PID and time constants Ti and Td decides the weight of I and D term in your controller respectively.
  1 Commento
Birdman
Birdman il 7 Feb 2018
Answer to
Hello Birdman and Thank you so much for your help. So what I understood is that I have to write the value in the PID(z) in simulink as showed in the pictures.is it correct!
See the attached figures, for both ideal and parallel PID, the thing that I explained in my answer.