Simulink integrator block initial conditions
8 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Raghuraman S
il 5 Feb 2019
Commentato: Wang Tao
il 24 Apr 2021
Hi, How does one specify initial conditions in simulink integrator block for times not t= 0 for example, y(3) =5;
0 Commenti
Risposta accettata
Fangjun Jiang
il 5 Feb 2019
utilize the "External reset" (set as rising) and "Initial ocndition source" (set as external).
Compare clock with t=3 and make it as the "External reset" signal.
4 Commenti
Fangjun Jiang
il 23 Apr 2021
Compare Clock with Constant block (value is 3) using the Relational Operator block, the output is trur or false.
Wang Tao
il 24 Apr 2021
Thanks for the prompt reply! I can get the answer for the time after t=3 with the y(3)=5 now. But the problem is for the time earilier than 3 as t<3, is not correct.
I am handling some two point boundary value problem, which y(3)=5 is the end/ final condition. Is there any way to solve this.
It seems can change the initial setting of integrator through properties, but there are no final condition settings.
Più risposte (0)
Vedere anche
Categorie
Scopri di più su Sources in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!