How to reset a stateflow state machine on external event?

49 visualizzazioni (ultimi 30 giorni)
Is it possible to re-initialize a state machine on an event generated by an other state machine?

Risposta accettata

TAB
TAB il 3 Set 2012
AFAIK, there is no such provision in stateflow. But you can design your stateflow chart logic with an external trigger input in such a way that it resets all the states and data (locals & outputs) when trigger is enabled.
  2 Commenti
Kaustubha Govind
Kaustubha Govind il 4 Set 2012
Modificato: John Kelly il 26 Feb 2015
The documentation also suggests placing Stateflow charts inside Enabled Subsystems and setting the "States when enabling" parameter to "reset" to force re-initialization: http://www.mathworks.com/help/stateflow/ug/controlling-states-when-function-call-inputs-reenable-charts.html?searchHighlight=States%20when%20enabling
Song
Song il 10 Feb 2016
Do you have a example of this? That would be extremely helpful

Accedi per commentare.