Does the Unexpected Backtracking error only occur when stateflow tries to excersize a transition with no exit, or does it look for this all the time? Also, does it have to be in a State Chart model trasition between states or does this work with what we call the "if, else ladder logic" stateflow model?

 Risposta accettata

It applies to both chart with states or chart of "ladder logic". It is looking at a junction
  • Does not have an unconditional transition path to a state or a terminal junction
  • Has multiple transition paths leading to it

Più risposte (0)