Simulink error using Data Store Read/Write
    5 visualizzazioni (ultimi 30 giorni)
  
       Mostra commenti meno recenti
    
I get the following error when I compile my model:
The block 'Util/Common/ReadToggled_LampTest' is reading from the data store 'Util/Common/Toggled_LampTest' before one or more blocks have written to this entire region of memory at time 0.0
I search the internet with different versions of the error that I got and I didn’t see anything on the error that I currently have. What do I need to do to fix this error without setting my configuration parameters from error to warning?
0 Commenti
Risposta accettata
  Kaustubha Govind
    
      
 il 10 Ott 2012
        Have you verified that 'Util/Common/ReadToggled_LampTest' is indeed not reading from 'Util/Common/Toggled_LampTest' before it's been written to? You can look at the block sorted order to see if 'Util/Common/ReadToggled_LampTest' is executing before the block that writes to 'Util/Common/Toggled_LampTest' does.
2 Commenti
  Kaustubha Govind
    
      
 il 11 Ott 2012
				Lucas: As the documentation that I linked to says "Simulink honors the block priorities that you specify unless they violate data dependencies" - so I think restructuring the model is the right way to go.
Più risposte (0)
Vedere anche
Categorie
				Scopri di più su Prepare Model Inputs and Outputs in Help Center e File Exchange
			