hdl coder error when compiling stateflow

1 visualizzazione (ultimi 30 giorni)
Amish Rughoonundon
Amish Rughoonundon il 29 Mar 2020
I can't figure out this error hdl coder is giving me when compiling a stateflow chart with parallel charts
Enumerated name 'IN_NO_ACTIVE_CHILD' is present in types 'state_type_is_TIMEOUT_WATCHER' and 'state_type_is_COUNT_IS_VALID'. Use unique enum type names for HDL code generation.
I attached the chart as pictures
Thanks for any help
  1 Commento
Amish Rughoonundon
Amish Rughoonundon il 29 Mar 2020
It seems hdl coder adds this state IN_NO_ACTIVE_CHILD by itself for the case where the state machine moves to the OFF state as shown below from the vhdl generated.
--case IN_ON:
sf_internal_predicateoutput_0 := hdlcoder_to_stdlogic((( NOT onoff) OR hdlcoder_to_stdlogic(timeoutCycles_unsigned = to_unsigned(0, 32))) = '1');
IF sf_internal_predicateoutput_0 = '1' THEN
is_COUNT_IS_VALID_next <= IN_NO_ACTIVE_CHILD;
is_TIMEOUT_WATCHER_next <= IN_NO_ACTIVE_CHILD;
is_timer_chart1_next <= IN_OFF;
ELSE
I am totally confused by why hdl coder would complain something it did itself. To me it would have made sense to move them back to the state connected to the default transitions????

Accedi per commentare.

Risposte (1)

Kiran Kintali
Kiran Kintali il 31 Mar 2020
Can you attach a small version of the model to reproduce the error?
"Enumerated name 'IN_NO_ACTIVE_CHILD' is present in types 'state_type_is_TIMEOUT_WATCHER' and 'state_type_is_COUNT_IS_VALID'. Use unique enum type names for HDL code generation."
We can check if the recommendation is valid or further improvements possible in the workflow.
Thanks
  1 Commento
Amish Rughoonundon
Amish Rughoonundon il 2 Apr 2020
I'll create a small model that reproduces the problem and post it here. Thanks