DQ model of three phase induction motor simulate faults
4 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
hi
i build the mathematical model for the induction motor using ABC to DQ equation
now I have difficulty to simulate faults like broken bar or short circuit fault in stator winding..
how i can do it in simulink ?
I would be grateful for your help
thanks.
2 Commenti
shubhranshu sharma
il 28 Set 2021
if any one did stator fault of IM in simulink please send.i will be very gratefull to you.thanks
i am also trying but facing difficulty. please send to- shubhranshusharma23@gmail.com
Risposte (1)
Joel Van Sickel
il 21 Nov 2022
You should use simscape models instead of simulink models, or you should derive a simulink model that is specifically designed the type of faults you want to inject. d/q transformations limit the types of faults that you can model, and equations typically change once a fault is injected so you will often need multiple sets of equations. Simscape models will support a set of predefined faults so that you are less likely to need a custom model, but not all possible faults can be included, so you have to read the documentaiton for the specific component that you are interested in.