Why don't pipe and orifice blocs in Simscape Fluids cause a pressure change ?

1 visualizzazione (ultimi 30 giorni)
I want to modelize a water flow going in a nozzle, especially the value of the pressure at the end of the nozzle orifice. However, no matter what the value of the pressure input or of the parameters of the blocks, the pressure differential of the several blocs are zero. My model has no pressure loss, the input and ouput pressures of the fluid are the same, which is problematic and unrealistic.
What could I do in order to change this ?
Thank you in advance.

Risposta accettata

Yifeng Tang
Yifeng Tang il 30 Mag 2021
The model does not have an outlet right now. The system is all pressurized to the value set by the constant pressure source, but there is no flow as I don't see an outlet reservoir. Zero flow, zero pressure drop. Add a reservoir to the right of the Orifice, you should see both flow and pressure drop. Add a flow rate sensor in line with the flow to show that on a scope, or use Simscape Result Explorer or Simulink Data Inspector.
Also, consider use Isothermal Liquid domain (blue color) instead of Hydraulics (yellow). Read about the difference and advantage of using the IL domain: https://www.mathworks.com/help/physmod/simscape/ug/upgrading-hydraulic-models-to-use-isothermal-liquid-blocks.html#mw_6db868a4-020d-402e-9cc4-aed14307a38f

Più risposte (0)

Categorie

Scopri di più su Hydraulic Elements in Help Center e File Exchange

Prodotti


Release

R2020b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!