how to design neurel network and train them to detect ,classify and locate the ten types of fault on transmission line

Risposta accettata

Greg Heath
Greg Heath il 29 Set 2013
1. Extract I features from each of N examples and form the IxN dimensional input matrix.
2. For each example, assign a column from the 10-dimensional unit matrix eye(10) to indicate the fault type and form the OxN (O=10) dimensional output target matrix.
[ I N ] = size(input)
[ O N ] = size(target)
3. Consult the PATTERNNET help and documentation examples
help patternnet
doc patternnet
4. Search the NEWSGROUP and ANSWERS using the keyword patternnet.
5. Practice on one or more of the MATLAB classification/pattern-recognition data sets
help nndatasets.
Thank you for formally accepting my answer