struct memeber can not be Simulink.Parameter?
13 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
dayu lai
il 29 Lug 2021
Risposto: Shivam Malviya
il 13 Set 2024
hi,
I am using HDL Coder to generate RTL code from simulink.
While I want some signal internal a simulink to be tunable, which names 'bp' for example. So I wrote following code:
bp = Simulink.Parameter;
bp.Value = [0;0;0];
bp.CoderInfo.StorageClass = 'ExportedGlobal';
Then the bp signal will appeared as a input port in RTL.
However, if I wrote like this:
reg.bp = Simulink.Parameter;
reg.bp.Value = [0;0;0];
reg.bp.CoderInfo.StorageClass = 'ExportedGlobal';
While generate RTL, it comes out error:
Invalid setting in '<some_block>' for parameter 'Value'.
error using slhdlcoder.SimulinkConnection/initModel
Expression 'reg.bp' for block '<some_block>' returns a Simulink.Parameter object that has property values that need to be evaluated. This object should be instantiated in a workspace and referenced by name in Simulink
So it seems struct member can not be simulink parameter?
1 Commento
Parker
il 11 Set 2024
I hope the Mathworks team will revisit this question and give an explanation for why this is not allowed. I have run into the same thing, where our team would like to store our parameters in a structure and use them in constant and gain blocks in our model, but Mathworks appears to have disallowed this starting with MATLAB r14sp3, per this older question
Risposta accettata
Shivam Malviya
il 13 Set 2024
Hi,
It appears that during the RTL code generation for the attached model, you are encountering the mentioned error due to the use of a struct variable with a field that is a Simulink.Parameter. In your use case, struct variables are necessary to bundle all the global tunable parameters together.
The current initialization of the `reg` variable is causing Simulink model compilation failure, which leads to an error during RTL code generation. To resolve this issue, please follow these steps:
- Instead of setting the field as a Simulink.Parameter, set the top-level struct as a Simulink.Parameter.
- Ensure that the appropriate bus object is set for the struct object of type Simulink.Parameter.
Below is the updated demo_param.m script, which correctly initializes the reg variable:
% Initialize the required value
thr_val = [5;6;7];
reg_val = struct('thr', thr_val);
% Create appropriate bus object
Simulink.Bus.createObject(reg_val);
regType = slBus1;
clear slBus1
% Create the Simulink.Parameter object
reg = Simulink.Parameter(reg_val);
reg.DataType = 'Bus: regType';
reg.CoderInfo.StorageClass = 'ExportedGlobal';
% Set required variables
DT_cnt = fixdt(0,8,0);
ts = 0.1;
However, input ports won't get generated in the RTL code for this scenario involving struct as a Simulink.Parameter.
For more details, please refer to the following documentation pages:
- https://www.mathworks.com/help/simulink/ug/using-structure-parameters.html#bu1k073
- https://www.mathworks.com/help/simulink/slref/simulink.bus.createobject.html
Best Regards,
Shivam Malviya
0 Commenti
Più risposte (2)
Kiran Kintali
il 1 Ago 2021
Can you share a sample model?
2 Commenti
Parker
il 11 Set 2024
I would love for an explanation from Mathworks about why this method of storing parameters is not allowed by Simulink
Kiran Kintali
il 11 Set 2024
These pages contain good info on allowed ExportedGlobal usage in HDL Coder
0 Commenti
Vedere anche
Categorie
Scopri di più su Speed Optimization in Help Center e File Exchange
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!