Stop Simulink simulation base don a variable value

27 visualizzazioni (ultimi 30 giorni)
Hello:
I want ot know how to stop a simulink simulation automatically when one of the variables reaches a negative value. I will run it through a .m file
Thank you in advance

Risposta accettata

Arnaud Miege
Arnaud Miege il 20 Giu 2011
Or use a Stop Simulation block. You will also need to construct the logic to create a boolean input signal to the block.
HTH,
Arnaud

Più risposte (2)

Fangjun Jiang
Fangjun Jiang il 20 Giu 2011
Add an "Assertion" block into your Simulink model. The block is in the library Simulink>Model Verification. It has the option to stop simulation when assertation fails. You need to construct a simple logic to compare your signal to zero.

Javier Guiterrez
Javier Guiterrez il 20 Giu 2011
Thank you for all the answers. the stop block is enough for my case. Thanks