How to implement voltage source inverter connected to a resistive load in Simscape in a proper way?
Hi Avinash, I see that you are implementing a high-fidelity model that is using N-Channel MOSFET blocks with gate driving circu...
4 mesi fa | 0
Small Signal Stability Analysis
Dear Basil, I studied small-signal stability of DC Power Distribution Systems during my PhD at University of South Carolina. My...
6 mesi fa | 0
Unable to tune buck multiloop controller by using Closed-Loop PID Autotuner
Dear Djordje, Please, have a look at the systematic workflow explained in the following technical article I coauthored: https:/...
7 mesi fa | 0
How to speed up simscape electrical simulation?
Dear Hassan Ali, I had a look at your model and I can notice that margins of improvements are in the direction of model fide...
7 mesi fa | 0
| accettato
How to Select Components for Circuit Design in MATLAB Given Limited Library Options?
Hi Naveen Sai, The Simulink library blockset is strictly speaking not specialized for physical modeling in the electrical domai...
7 mesi fa | 0
I am unbale to connect three phasr VSI inverter model with my MUX input, because they are from different library. How can i coneect ?
Hi Snehil, You cannot connect Physical Conserving ports shaped as squares to Simulink signals shaped as arrow heads. To learn...
7 mesi fa | 0
Where Can I Download the PID Controller Tuning for a Buck Converter Example?
Hi, If you are looking for more recent content, please have a look at the following links: Technical article (no files, but co...
10 mesi fa | 0
Can we change parameters inside 'block parameters' of Ideal IGBT block?
Hi, A little head-up on your task. I see that you are calculating the efficiency by using Simulink blocks. Even though theore...
oltre un anno fa | 1
why is it impossible to use the PID tuning app when tuning a PID controller used in circuits that have PWM switchings?
Dea Hassan, The failure in the linearization process is normal due to the discontinuities associated to switching events. This...
circa 3 anni fa | 0
Why is the settling value of my TF so high when compared to my output value? How can I resolve this?
Dear Samuel, the discrepancy you're getting may be explained by the presence of other nonidealities you model with Simscape Elec...
oltre 3 anni fa | 0
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
Dear Samuel, The difficulties you are encountering are understandable since when you tune a specific gain of your PID controlle...
oltre 3 anni fa | 0
In "frestimate(modelname,op,io,in)", it is required for each of the linearization input I/O points that the sample time of the Simulink signal where it is located is one of the following:
Hi, both input linearization point and output measurement point are required to be equally sampled and must match the perturbati...
oltre 4 anni fa | 3