Community Profile

photo

Dr Narayanaswamy P R Iyer


Last seen: 2 mesi fa Attivo dal 2017

M.E.(Power Electronics and Drives), UTS, NSW, Australia. Ph.D.(Power Electronics and Drives), Curtin University of Technology, Perth, WA, Australia. Received B.Sc.(Engg)(Electrical) and M.Sc.(Engg)(Power systems) degrees from Kerala University and Madras University respectively. Published the following text books: 1) "Power Electronic Converters: Interactive Modelling Using Simulink", CRC Press, 2018. 2) AC to AC Converters: Modelling, Simulation and Real-Time Implementation Using SIMULINK", CRC Press, 2019. Present MATLAB Version: R2022a. MATLAB License Number: 40513742 Operating System: Microsoft Windows 10 Home Version 10.0 (Build 14393) Java Version: Java 1.8.0_121-b13 with Oracle Corporation Java HotSpot(TM) 64-Bit Server VM mixed mode ----------------------------------------------------------------------------------------------------- P.R. NARAYANASWAMY. Dr NARAYANASWAMY P R IYER EMAIL: nswamy.iyer@gmail.com

Programming Languages:
C++, C, Java, MATLAB, SQL, HTML, Fortran
Spoken Languages:
English, Hindi

Statistiche

  • Knowledgeable Level 1
  • Thankful Level 2
  • 3 Month Streak
  • First Answer
  • Thankful Level 1

Visualizza badge

Content Feed

Visto da

Risposto
Are there any MATLAB Simulink models for Indirect Matrix Converters, especially Sparse Matrix Converter?
You may refer to my text book given below: NARAYANASWAMY P R IYER: "AC TO AC CONVERTERS: MODELING, SIMULATION AND REAL-TIME...

3 mesi fa | 0

Risposto
How to find THD?
Check the result by setting sample time to zero and also by setting it to 50e-6 Second.

3 mesi fa | 0

Risposto
Hi. In Simulink modeling, what can we do to ensure that the switching waveforms of the duty cycle and 1-duty cycle are not in phase?
Connect q1 to NOT gate and use Data Type Conversion block if error message occurs.Output of NOT gate is q3. Alternatively connec...

4 mesi fa | 0

Risposto
Better solver for simscape power electronics simulation
In case of uncertainty as to which solver to be used, select AUTO solver selection mode from the drop down menu.

5 mesi fa | 0

Risposto
What solver settings is best for a closed loop Dual active bridge simulation??
Usually ode23tb will be sufficient. If you are unsure select auto (automatic solver selection) mode.

9 mesi fa | 0

Risposto
What is an efficient way to do PID tuning in a model with long computing time?
You may use Ziegler-Nicholas step response or else frequency response method for tuning PID controllers.

10 mesi fa | 1

| accettato

Risposto
Controling multiple switches in a multiple input DC-DC converter
Hi Mohammad Alsalman: You have to use combined combinational and sequential logic. I give below how to generate gate pulse fo...

circa un anno fa | 0

Risposto
Controling multiple switches in a multiple input DC-DC converter
Hi Mohammad Alsalman: You have to use combined combinational and sequential logic. I give below how to generate gate pulse fo...

circa un anno fa | 0

Risposto
Explaining the function of certain blocks
Hi: Assume that pulse generator output is vg and armature voltage control signal output is vcon. The top mux output, vcon, bot...

circa un anno fa | 0

Risposto
I want to do Primary frequency response of DFIG Wind Turbine in script form (MATLAB).
Hi: Please refer to the following text book: NARAYANASWAMY P R IYER: "Power Electronic Converters Interactive Modelling Usin...

circa un anno fa | 0

Risposto
How to find people to work on a collaborative project
I can work if the project falls within the broad area of Power Electronics and Drives. DR. NARAYANASWAMY P R IYER EMAIL: ns...

circa un anno fa | 0

| accettato

Risposto
I want to do Primary frequency response of DFIG Wind Turbine in script form (MATLAB).
Hi: Try using EMBEDDED MATLAB Function in SIMULINK.

circa un anno fa | 0

Risposto
How to find THD?
If your model is in SIMULINK, use THD module from Simscape / Electrical / Specialized Power Systems / Sensors and Measurements ...

circa un anno fa | 0

Risposto
How To Input Duty Ratio into Pulse Generator
Enter period as 20e-6 Seconds and pulse width as 50.

oltre un anno fa | 1

Risposto
Torque control of PMSM motor- Need help
Hi: Torque set point is the rated machine torque. Torque set point is required to calculate id and iq reference values and stat...

oltre un anno fa | 0

Risposto
Help understanding transformers in simulink
The results appears alright. The spikes in waveform could be due to inductance of transformer windings compared to their resista...

oltre un anno fa | 0

Risposto
Defining pmsm parameters for delta configuration
The resistance and inductance values must be multiplied by 2/3 to get the per phase values for delta configuration. Thanks. DR....

quasi 2 anni fa | 0

Risposto
link a full bridge DC/AC to an induction machine
Hi: The PWM output is a gate pulse and is given to the G input of inverter through a four pulse gate multiplexer. The + and - te...

quasi 2 anni fa | 0

Risposto
Why does differentiating PID feedback break the system?
Clock module.

quasi 2 anni fa | 0

Risposto
Why does differentiating PID feedback break the system?
Hi: Instead of integrator at the output of convert to RPS module, use a multiplier block along with time block or time module an...

quasi 2 anni fa | 0

Risposto
How to develop Behavioral model of gate driver integrated circuit using specialized power system library blocks?
Shiny: Please refer to the following text book: NARAYANASWAMY P R Iyer: "AC to AC Converters Modelling, Simulation and Real-T...

circa 2 anni fa | 0

Risposto
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
For 8 V output, your duty-ratio should be 2/3 (0.67) for given input voltage.

circa 2 anni fa | 0

Risposto
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
TF is one method. You know the desired output voltage and duty-ratio D. Use this in the model to get open loop voltage response....

circa 2 anni fa | 0

Risposto
How can I remove the few peaks before the overshoot, so I only have the overshoot peak and then it directly transition into steady state?
You have NOT mentioned anything about triangle carrier frequency. First obtain output voltage response without PI controller. Th...

circa 2 anni fa | 0

Risposto
my firing angle on this triac does not work correctly ?
For switching thyristors, you may refer to the following text book: NARAYANASWAMY P R IYER: "Power Electronic Converters Inte...

circa 2 anni fa | 0

Risposto
Problem At Sistem On Chip (SOC,PIL) Example Application
Most probably it could be due to insufficient RAM memory. Please check your PC RAM with the version of MATLAB specific requirem...

oltre 2 anni fa | 0

Risposto
Problem At Sistem On Chip (SOC,PIL) Example Application
Check your PC RAM memory with that specified by MATHWORKS for the MATLAB version used.

oltre 2 anni fa | 0

Risposto
Can you open an older simulink models and reference models in a newer version and build from the newer simulink?
I think the model developed using 2013b in Simulink can be opened with 2020b.

oltre 2 anni fa | 0

Risposto
Analog PID controller to Discrete PID controller
Analog PID Controller. Find TF of analog PID Controller and use command c2d in MATLAB.

oltre 2 anni fa | 0

Risposto
How to integrate op-amp into Simulink model using Specialized Power Systems Components
Use Controlled Current Source from Simscape ---> Electrical Sources Library, Inductor and op.amp from Simscape ----> Electrical ...

oltre 2 anni fa | 0

Carica altro