Threshold Data
In many cases, a conservative maintenance schedule means machines rarely fail. This can mean run-to-failure data or lifetime data is not available. However, you likely have information on prescribed threshold values—for example, the temperature of a liquid in a pump cannot exceed 160 ˚F (71 ˚C) and the pressure must be under 2,200 psi (155 bar). With this threshold information, you can fit degradation models to condition indicators extracted from sensor data, which change linearly or exponentially over time.
These degradation models estimate RUL by predicting when the condition indicator will cross the threshold. They can also be used with a fused condition indicator that incorporates information from more than one sensor using techniques such as principal component analysis.
Figure 3 shows an exponential degradation model that tracks failure in a high-speed bearing used in a wind turbine. The condition indicator is shown in blue. The degradation model predicts that the bearing will cross the threshold value in approximately 9.5 days. The region shaded in red represents the confidence bounds for this prediction.