Azzera filtri
Azzera filtri

Info

Questa domanda è chiusa. Riaprila per modificarla o per rispondere.

Using Matlab coder for protecting blocks with power ports

2 visualizzazioni (ultimi 30 giorni)
Kumar
Kumar il 21 Dic 2011
Chiuso: MATLAB Answer Bot il 20 Ago 2021
Hi, I am new to Matlab-simulink. I am trying to protect a block that I am using in my project. I tried using Matlab coder. But, when I try to reference the model after protecting it, the referencing block does not recognize anything other than the signal ports. It would be really helpful if anyone can share their experience with matlab coder.
Thanks, Kumar
  3 Commenti
Walter Roberson
Walter Roberson il 21 Dic 2011
"power ports" ? Are you using SimPower ?
Kumar
Kumar il 22 Dic 2011
Yes I am using SimPower. Sorry to confuse everyone with the wrong jargon. I am using Simulink.ModelReference.protect command to create .mdlp file and then reference it. When I reference the .mdlp file, the PMC_ports are not recognized. I am not able to get any output from the inverter inside the referenced protected model.

Risposte (1)

Fangjun Jiang
Fangjun Jiang il 21 Dic 2011
To be precise, it's Simulink Coder, not MATLAB Coder. See Protecting Referenced Models
  3 Commenti
Kaustubha Govind
Kaustubha Govind il 22 Dic 2011
By PMC_ports, do you mean ports with physical signals? If yes, model reference blocks do not support such signals at their boundaries. Perhaps you could consider converting them to a regular Simulink signal before outputting them from your block.
Fangjun Jiang
Fangjun Jiang il 22 Dic 2011
Sorry I don't have SimPower. My experience on model reference is with Simulink only.

Questa domanda è chiusa.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by