Azzera filtri
Azzera filtri

Why do I get a different response when using the "step" command in the command line and the scope in Simulink?

71 visualizzazioni (ultimi 30 giorni)
I have a MIMO (10 outputs and 5 inputs) state transition matrix I don't understand why do I get different responses when invoking a step input in the command line and in Simulink. Can someone give me a light on this?

Risposta accettata

Birdman
Birdman il 30 Ott 2017
Modificato: Birdman il 30 Ott 2017
It is because of the solver. In Simulink, you probably use variable step solver, which is more accurate. In MATLAB Command line, you can overcome this situation by making the simulation with a small step size that you define, so you will get more accurate results.
t = 0:1e-6:10;
step('your model',t)
Try the code above.