Reset integrator no initial condition in Simulink
69 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
Hi,
A reset controller uses an integrator which can reset itself. This can be implemented in Simulink using the 'External reset' option of the integrator element. The corresponding reset matrix can be implemented by showing the state port and by setting the Initial Condition Source to external.
In the image you see the an integrator, which resets to a partial value of the current state (through reset matrix R) when the input signal goes through zero. To implement the reset matrix R in the integrator, I have to set the Initial Condition Source to external. When I do this, I can no longer apply an initial condition.
Is there some way around to apply an initial condition at the start of the simulation?
3 Commenti
Risposte (1)
Fangjun Jiang
il 11 Gen 2018
I would insert a "Unit Delay" block after the "Gain" block and feed the output to "X0" port.
0 Commenti
Vedere anche
Categorie
Scopri di più su General Applications in Help Center e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!