Variant subystems with mixed discrete/continuous?
5 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
I am trying to use a variant subsystem to switch between a continuous block and a discrete block - a derivative block and a difference block, respectively. When the variant is set to the derivative block, the diagram will be used to run a simulation directly. When the variant is set to the difference block, the diagram will be used to generate code.
In principle, this should work, since only one variant is active at a time. When I generate code, I want the continuous variant to be left out completely, as it will be inactive. However, when I try to generate code, it complains that there are continuous states, so it can't (presumably because the derivative block is still there, even though it is inactive.) Is there some way that I can configure it to completely ignore non-active blocks, depending on how my variants are set?
2 Commenti
Azzi Abdelmalek
il 11 Ago 2012
Modificato: Azzi Abdelmalek
il 11 Ago 2012
what do you mean to generate code?
Risposte (2)
Guy Rouleau
il 13 Ago 2012
I would be surprised if this is because of the derivative block. Usually, inactive variant should completely disappear.
- Ensure the option "Generate preprocessor conditional" is disabled. Otherwise both variants will be present... this is the only reason I know for 2 variants to be present.
- Use sample time colors or Simulink.BlockDiagram.getInitialState to identify which block has continuous state in your model.