pole placement in M-file
16 visualizzazioni (ultimi 30 giorni)
Mostra commenti meno recenti
hello every one ... how can i determine (p) in pole placement code K = place(A,B,p)
0 Commenti
Risposta accettata
Più risposte (3)
Shashank Prasanna
il 20 Lug 2013
shahad, place is used to perform pole placement using state feedback. The output K is the feedback gain matrix.
PLACE is not an optimal control methodology and does no come up with good p values. It merely attempts to place at the specified location and generates the gain matrix.
You question seems to be related to: How do I generate this stable optimal p?
There are numerous answers to that question but a popular one is linear quadratic controller (LQR):
The first output argument is the gain matrix K and the 3rd output argument 'e' are you poles which are automatically generated when the optimization is performed.
4 Commenti
Azzi Abdelmalek
il 16 Ago 2013
Shashank, What I mean by optimal poles is poles that provide a system optimal performances (acceptable stability margin, and optimal performances to be defined by the user).
Azzi Abdelmalek
il 20 Lug 2013
Modificato: Azzi Abdelmalek
il 20 Lug 2013
p is the poles vector you have to impose to your system in closed loop.
Example:
A=[-6 -5;1 0];
b=[1;0]
The size of A is 2x2 then the length of the pole vector p should be 2
p=[-5 -10] % the poles should be stables (real(p)<0)
%or
p=[-2+j -2-j]
place(A,b,p)
4 Commenti
Azzi Abdelmalek
il 20 Lug 2013
Like I said the pole to impose should be real or complex numbers with real part obligatory negative. This is enough to get a stable control, for optimal performances, you have to read the effects of poles on the system.
Nagesh
il 1 Mar 2024
A=[-6 -5;1 0];
b=[1;0]
p=[-5 -10] % the poles should be stables (real(p)<0)
%or
p=[-2+j -2-j]
place(A,b,p)
1 Commento
Sam Chak
il 1 Mar 2024
Hi @Nagesh
Your response didn't fully address the original question. In order to determine the control gain using the place() command, the user must input the poles that result in the Hurwitz characteristic polynomial. These poles specifically correspond to the closed-loop system and generate the desired response specified by the user. Your answer deserves votes if you could provide a practical example to illustrate this.
Let's consider a simple Double Integrator system. If we need to meet performance specifications such as a percent overshoot of ≤ 9% and a settling time of ≤ 1 second, how would you determine the target poles?
A = [0, 1; 0, 0]; % state matrix
B = [0; 1]; % input matrix
C = [1, 0]; % output matrix
D = 0*C*B; % direct matrix
sys = ss(A, B, C, D)
Gp = tf(sys)
Vedere anche
Categorie
Scopri di più su Systems of Nonlinear Equations in Help Center e File Exchange
Prodotti
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!