photo

Guanwei Zeng


Last seen: circa un anno fa Attivo dal 2021

Followers: 0   Following: 0

Statistica

  • Thankful Level 2
  • Thankful Level 1

Visualizza badge

Feeds

Visto da

Domanda


Fuel cells connected to converter. Error: Input current must be less than Maximum expected supply-side current.
Hello, I want to replace the battery in the model(Electric Aircraft Model in Simscape - File Exchange - MATLAB Central (mathwork...

circa 3 anni fa | 1 risposta | 0

1

risposta

Risposto
Error: block_diagram does not have a parameter named 'payloadMass'
I also tried the get(gcbh) function to see the parameter. checkbox_payload_mass: 'on' paylo...

oltre 3 anni fa | 1

Domanda


Error: block_diagram does not have a parameter named 'payloadMass'
Hello I have a model named ‘asbHybridAircraft4_7’, and I want to run it with the parameter 'payloadMass' configured with the s...

oltre 3 anni fa | 1 risposta | 0

1

risposta

Domanda


Moist Air Modeling error: Solver was unable to reduce the step size
Hi, I'm developing a hydrogen tank in which the hydrogen is removed according to the Fuel Rate(input port1). The model is suc...

oltre 3 anni fa | 1 risposta | 0

1

risposta

Domanda


Fuel Cell Stack to DC-DC converter error
Hello everyone, I'm a student and quite new to Simulink. I download the Example(https://www.mathworks.com/help/releases/R20...

quasi 4 anni fa | 1 risposta | 0

1

risposta

Domanda


DC-DC converter Error Initial conditions solve failed to converge.
Hi, I'm quite new to Simulink and want to test the function of DC-DC converter. The picture below is the model I developed. H...

quasi 4 anni fa | 2 risposte | 0

2

risposte

Domanda


How to see the values of the Parameters defined as variables in the Examples given by Simulink?
Hi, reacently I donwnload a Simulink Example(https://www.mathworks.com/help/releases/R2020a/aeroblks/Electrical-Component-Analys...

quasi 4 anni fa | 1 risposta | 0

1

risposta

Risposto
Link blocks in different libraries[Fuel Cell Stack(Specialized power system) and Motor & Drive (Simscape electrical)
I fonund this bolck is more efficient as it can transform the signal directly. https://www.mathworks.com/help/physmod/sps/inter...

quasi 4 anni fa | 0

| accettato

Risposto
Link blocks in different libraries[Fuel Cell Stack(Specialized power system) and Motor & Drive (Simscape electrical)
Finally, I found a solution. First, measure the voltage of the Fuel Cell Stack and use the Simulink-PS converter to transform th...

quasi 4 anni fa | 0

Domanda


Link blocks in different libraries[Fuel Cell Stack(Specialized power system) and Motor & Drive (Simscape electrical)
The two blocks contained in the two libraries with red circle respectively. I want to link the two blocks together as th...

quasi 4 anni fa | 2 risposte | 0

2

risposte

Domanda


The meaning of gray square port
I want to connect a DC voltage source to a converter, while the port of DC source is gray square and the port of converter is bl...

quasi 4 anni fa | 2 risposte | 0

2

risposte